Documentation / API
Devices & tokens
Create, list, update and delete devices; issue and regenerate their ingestion token; set their profile, network identifiers, MQTT topics, position and attributes; configure an on-site gateway.
All paths are relative to https://apiv1.opensensorcloud.com/api/v1. Reading requires membership; writing requires the editor role, except MQTT topics (admin).
The device object
{
"id": "8dec3c85-313d-4c4c-bb00-c8fad203200e",
"name": "Greenhouse A",
"description": "",
"kind": "device",
"gatewayId": null,
"profileId": "9f10a175-69ef-4a3d-b39b-006705af34e7",
"location": { "latitude": 45.764, "longitude": 4.8357, "source": "manual", "radiusM": null, "updatedAt": null },
"lastSeenAt": "2026-11-13T09:24:57.059Z",
"createdAt": "2026-11-13T09:24:56.956Z"
}
| Field | Meaning |
|---|---|
kind |
device, or gateway (on-site Modbus / OPC-UA gateway, or MQTT controller / bridge) |
gatewayId |
for a device created by a gateway or controller, that gateway's id |
location |
null, or the position with its source: manual (typed), gps (decoded points), network (Sigfox, with radiusM precision in metres); updatedAt = time of the measurement that set it |
lastSeenAt |
last accepted message; the UI shows a device as online below 5 minutes |
List and read
GET /orgs/{orgId}/devices
All devices of the organization, sorted by name (array of device objects), each with profileName (name of its profile, null without one), devEui and sigfoxId (null when not set). With ?include=deleting, the devices being deleted are listed too, each device with deleting: true or false.
GET /orgs/{orgId}/devices/{deviceId}
The device plus its details and channels:
{
"id": "8dec3c85-…", "name": "Greenhouse A", "kind": "device", "profileId": "9f10a175-…",
"devEui": null, "sigfoxId": null, "mqttTopics": [], "attributes": { "site": "north" },
"channels": [
{ "key": "temperature", "type": "number", "unit": "°C", "label": "Temperature", "min": -10, "max": 50,
"declared": true, "lastTs": "2026-11-13T09:24:56.936Z", "lastValue": 25.5 },
{ "key": "door", "type": "bool", "unit": null, "label": "Door open", "min": null, "max": null,
"declared": true, "lastTs": "2026-11-13T09:24:56.936Z", "lastValue": false }
]
}
channels merges the channels declared by the profile (declared: true, shown before any measurement) and those actually received. type is number, bool or string.
Create
POST /orgs/{orgId}/devices — editor
{ "name": "Greenhouse A", "kind": "device", "description": "" }
kind defaults to device. 201:
{
"device": { "id": "8dec3c85-…", "name": "Greenhouse A", "kind": "device", "…": "…" },
"token": "osc_dev_W1axHkMk6FxUcgDgoUeXxhS209oyZz8Seas-p2fceMo",
"ingestUrl": "https://apiv1.opensensorcloud.com",
"mqtt": {
"host": "mqtt.opensensorcloud.com", "port": 1884, "tlsPort": 8883,
"username": "8dec3c85-313d-4c4c-bb00-c8fad203200e",
"topic": "osc/demo/8dec3c85-313d-4c4c-bb00-c8fad203200e/telemetry"
}
}
The token is returned only here (and on regeneration): it is stored hashed. tlsPort is absent when the instance does not offer MQTT over TLS. Error: 403 device_quota_reached.
Token
POST /orgs/{orgId}/devices/{deviceId}/token — editor
Issues a new token and invalidates the previous one immediately. 200 with { token, ingestUrl, mqtt } as above.
Update
PATCH /orgs/{orgId}/devices/{deviceId} — editor
Only the given fields change.
{
"name": "Greenhouse A",
"description": "North site, row 3",
"profileId": "9f10a175-…",
"devEui": "70-B3-D5-7E-D0-00-12-34",
"sigfoxId": "1A2B3C",
"location": { "latitude": 45.764, "longitude": 4.8357 },
"attributes": { "site": "north" },
"mqttTopics": ["tele/plug-livingroom/#"]
}
| Field | Rules |
|---|---|
profileId |
a profile of the organization, or null |
devEui |
LoRaWAN devEUI, 16 hex characters (separators and case ignored), unique in the organization (409 dev_eui_taken), or null |
sigfoxId |
1 to 8 hex characters, stored lowercase without leading zeros, unique in the organization (409 sigfox_id_taken), or null |
location |
both coordinates (latitude −90…90, longitude −180…180), or null to clear it (a network or GPS position may then place the device again) |
attributes |
up to 20; keys ^[a-z][a-z0-9_]{0,31}$, values 1 to 64 characters without / + # $ or spaces. For a gateway bound to a profile with a topic template, they are the template variables |
mqttTopics |
admin only (403 mqtt_topic_admin_only); up to 5 MQTT filters; see below |
MQTT topic filters: + takes a whole level, # only last; the first level must be a literal name; $… and osc/… are reserved. A filter may not overlap any other device's filter on the whole instance (409 mqtt_topic_taken). For a controller (gateway with a topic-template profile): 400 template_needs_free_variable if every variable is set but one should stay free, 400 unknown_template_variable for an attribute that is not a template variable.
Returns 200 with the device object.
Delete
DELETE /orgs/{orgId}/devices/{deviceId} — editor
Deletes the device, its token, channels, measurements and raw messages. Asynchronous: answers 202 { "status": "deleting" } at once. From then on the device is gone for the API (404, absent from lists, dashboards and selectors, not counted in the device quota), its token is revoked and its devEUI, Sigfox ID and MQTT topics are released (they can be given to another device at once); ingestion refuses it. Its history is then removed in the background, which may take a few minutes for a long one. Deleting it again meanwhile answers 202 again; once it is gone, 404. The device.delete audit entry stays.
Measurements
See Telemetry for GET …/devices/{deviceId}/telemetry and GET …/devices/{deviceId}/export.csv.
Gateway configuration (Modbus / OPC-UA)
For a device of kind gateway running the on-site gateway.
GET /orgs/{orgId}/devices/{deviceId}/gateway-config
PUT /orgs/{orgId}/devices/{deviceId}/gateway-config — editor
{
"pollSeconds": 10,
"sources": [
{
"id": "plc1", "name": "PLC", "deviceId": "93fae36f-…", "protocol": "modbus",
"transport": { "type": "tcp", "host": "192.168.1.20", "port": 502 },
"unitId": 1,
"registers": [
{ "key": "pressure", "address": 0, "kind": "holding", "format": "float32", "wordOrder": "big", "scale": 1, "offset": 0 }
]
},
{
"id": "opc1", "name": "OPC-UA server", "deviceId": "6557e8f4-…", "protocol": "opcua",
"endpoint": "opc.tcp://192.168.1.30:4840",
"nodes": [ { "key": "speed", "nodeId": "ns=2;s=Line1.Speed" } ]
}
]
}
pollSeconds: 1 to 3600. Up to 100 sources, each publishing to the child devicedeviceId.- Modbus
transport:tcp(host,port502) orrtu(pathof the serial port,baudRate9600,paritynone/even/odd). Registers: 0-basedaddress,kindholding/input/coil/discrete,formatint16/uint16/int32/uint32/float32/bool,wordOrderfor 32-bit formats, thenvalue × scale + offset. - OPC-UA: security mode "None" only, optional
username/password.
The gateway downloads its configuration from the ingestion service, see Ingestion.