Documentation / API
Ingestion
Send measurements over HTTP (JSON, batches, gzip, binary) or MQTT (topics, authentication, QoS, custom topics), and let an on-site gateway download its configuration.
Message format
The same body is accepted over HTTP and MQTT.
{ "temperature": 21.4, "humidity": 48, "door": false, "status": "ok" }
{ "ts": "2026-11-13T08:00:00Z", "values": { "temperature": 21.4 } }
[
{ "ts": "2026-11-13T08:00:00Z", "values": { "temperature": 21.4 } },
{ "ts": "2026-11-13T08:10:00Z", "values": { "temperature": 21.9, "humidity": 47 } }
]
- Keys:
^[A-Za-z0-9_.-]{1,64}$, at most 100 per element. Each new key becomes a channel of the device. - Values: finite number, boolean, or text up to 1,024 characters.
nullmeans "no value for this key in this message" and is skipped; at least one value must be non-null. ts: optional, ISO 8601 or anythingDateparses; default = reception time. At most one hour in the future.- A message holds at most 1,000 points (keys × elements); beyond, it is rejected as a whole.
- A message is ingested entirely or not at all.
- With a profile
timestampKey(e.g.date_time), flat objects carrying their own time are accepted:{ "date_time": "2026-11-11T17:07:36.437Z", "hp": 10.7 }. - Any other JSON, or binary data, goes through the profile's decoder (see Profiles & decoders).
HTTP
POST https://apiv1.opensensorcloud.com/ingest/v1/telemetry
curl -X POST https://apiv1.opensensorcloud.com/ingest/v1/telemetry \
-H "Authorization: Bearer osc_dev_…" \
-H "Content-Type: application/json" \
-d '{"temperature": 21.5, "humidity": 48}'
| Content type | Handling |
|---|---|
application/json |
the format above, or the profile's decoder for another JSON shape |
application/octet-stream |
raw bytes, passed to the profile's decoder |
gzip (Content-Encoding: gzip, or a body starting with the gzip bytes 1f 8b) |
decompressed first (at most 1 MiB once decompressed), then as above |
gzip -c batch.json | curl -X POST https://apiv1.opensensorcloud.com/ingest/v1/telemetry \
-H "Authorization: Bearer osc_dev_…" -H "Content-Type: application/json" \
-H "Content-Encoding: gzip" --data-binary @-
The request body is limited to 1 MiB.
Responses:
| Status | Body | Meaning |
|---|---|---|
202 |
{ "accepted": 2 } |
number of points accepted |
400 |
{ "error": "validation", "detail": "(corps) : Invalid input" } |
invalid body; detail lists path : message for each problem ((corps) = the whole body) |
401 |
{ "error": "unauthorized" } |
missing or wrong token |
413 |
{ "error": "too_many_points", "detail": "1200 points, maximum 1000" } |
too many points |
413 |
{ "error": "payload_too_large", "detail": "…" } |
gzip body too large once decompressed |
429 |
{ "error": "rate_limited", "detail": "…" } + Retry-After: 1 |
device rate exceeded (3,000 messages per minute on average) |
429 |
{ "error": "quota_exceeded", "detail": "daily message quota reached (100000/day)" } + Retry-After: <seconds until midnight UTC> |
organization daily quota reached |
A rate limit or quota counts one message per request, whatever its number of points: batching saves quota. Rejected messages are visible, with their reason, in the device's live debug view.
MQTT
| Setting | Value |
|---|---|
| Host | mqtt.opensensorcloud.com (the mqtt.host returned with the token) |
| Ports | 8883 MQTT over TLS (recommended); plaintext port as returned in mqtt.port, for trusted networks only; WebSocket over TLS at wss://apiv1.opensensorcloud.com/mqtt (to verify on the public instance) |
| Username | the device id |
| Password | the device token |
| Topic | osc/<org slug>/<device id>/telemetry |
| QoS | 0 and 1 |
mosquitto_pub -h mqtt.opensensorcloud.com -p 8883 --capath /etc/ssl/certs -q 1 \
-u 8dec3c85-313d-4c4c-bb00-c8fad203200e -P osc_dev_… \
-t osc/demo/8dec3c85-313d-4c4c-bb00-c8fad203200e/telemetry \
-m '{"temperature": 21.5}'
- The payload follows the message format above; binary and gzip payloads are accepted as over HTTP.
- A device can only publish on its own topics and cannot subscribe to anything. A message published elsewhere is refused by the broker.
- MQTT has no response: rejected messages (invalid, rate limit, quota) are dropped and shown in the live debug view.
Custom topics and topic templates
For equipment that imposes its own topics, a device may reserve up to 5 MQTT filters (mqttTopics, see Devices), and a gateway bound to a profile with a topicTemplate reserves the filter derived from its attributes (see Profiles). The equipment then publishes on those topics with the device's id and token:
- standard JSON is accepted as is;
- a bare value (
45.2) becomes a channel named after the last topic level (…/relay/0/power→power); - anything else goes to the profile's decoder, which receives the topic in
meta.topic.
With a template, each value of the free variables (e.g. {unit}) identifies a child device, created on its first message.
On-site gateway
A gateway device publishes its children's measurements on each child's own topic, osc/<org slug>/<child device id>/telemetry, with the gateway's credentials.
Gateway configuration
GET https://apiv1.opensensorcloud.com/gateway/v1/config
Called by the on-site Modbus / OPC-UA gateway with its own token (Authorization: Bearer osc_dev_…).
{
"version": "3f2a…",
"orgSlug": "demo",
"gatewayId": "2e5de97a-8d20-477e-be9e-add38de17e3f",
"config": { "pollSeconds": 10, "sources": [ … ] }
}
config is the configuration saved with PUT …/devices/{id}/gateway-config (see Devices). The response has an ETag; send it back in If-None-Match to get 304 Not Modified when nothing changed (the gateway polls and reloads hot). Errors: 401 (token), 403 not_a_gateway (the device is not of kind gateway).